What does the glue actually touch?
M-6140 and M-6145 are folder-gluer candidates for UV-coated, laminated and varnished carton joints. Their stated viscosity is 7,000–14,000 mPa·s, but the actual glue-contact surfaces determine the trial. Open the seam, mark where each flap touches the adhesive, and compare printed coating with any exposed-board strip before choosing a model.
Which conditions belong in the trial record?
Record both bonding surfaces, nozzle or disc geometry, bead position, line speed and compression time. The folder-gluer family has a source-stated benchmark up to 420 m/min and a 48-hour cure reference. Those figures do not diagnose pop-open: preserve failed seams and distinguish an early opening from separation after conditioning.
- The bonding surfaces
- Name the board, film or varnish on each side of the joint. Mark any glue-free strip or abraded area.
- The folder-gluer setup
- Record the nozzle or wheel, bead position, running speed and time under compression.
- The failed seam
- Show whether the seam springs open at delivery or separates after packing. Note which surface carries the adhesive after opening.
How should the trial be compared with current production?
Compare M-6140 or M-6145 with the current adhesive on the same blank batch and controlled setup. Agree the 24-hour ambient inspection and the separate 48-hour cure reference, then document seam opening and fiber tear. Use the listed thermal exposures only after confirming the test construction and evaluation method with the manufacturing partner.