What is the ambient fiber-tear benchmark?
Condition bonded samples for 24 hours at 5–35°C, then inspect for opening and hand-tear fiber separation. The stated criteria are zero opening and at least 90% fiber tear; the M-6123–M-6328 rigid-box series states at least 95%. Agree the sample construction and inspection method before comparison.
| Series | Conditioning | Stated pass criteria |
|---|---|---|
| Packaging adhesives | 24 h at 5–35°C | Zero opening; hand-tear fiber tear ≥90% |
| Rigid-box adhesives | 24 h at 5–35°C | Zero opening; hand-tear fiber tear ≥95% |
Which cold and hot exposures apply to each adhesive series?
Folder-gluer grades such as M-6140 and M-6145 use the −20°C and 60°C reference exposures below. Rigid-box grades such as M-6123 and M-6192 use −36°C and 80°C exposures. These are separate conditioning protocols, not a continuous service-temperature rating or proof that every bonded construction will pass.
| Series | Cold exposure | Hot exposure |
|---|---|---|
| Folder-gluer cold glue | −20°C / 24 h | 60°C / 24 h at 85% RH |
| Rigid-box cold glue | −36°C / 24 h | 80°C / 48 h at 95% RH |
How are nozzle cleaning, foaming and glue slinging evaluated?
The spray benchmark uses 10 kg of continuous application, an average nozzle-wipe interval of at least 30 minutes and cleaned residue area no greater than 20%. Roller and disc checks use 4-hour and 10-minute runs respectively. Confirm the applicable grade, equipment settings and scoring procedure before treating these as acceptance limits.
| Application | Run condition | Observation or benchmark |
|---|---|---|
| Spray gun | 10 kg continuous spraying | Average nozzle-wipe interval ≥30 min; cleaned residue area ≤20% |
| Roller | 4 h running | Inspect foam and residue retained by 160-mesh filtration |
| Disc | 10 min running | Assess glue slinging and stability; folder-gluer series reference up to 420 m/min |
Which packaging sizes should a sampling enquiry specify?
Request a 20 kg pail, 50 kg drum or 1000 kg IBC tote according to the trial or production plan. State the required grade, destination and current TDS/SDS request. Confirm format availability, storage conditions and handling requirements for that grade; the packaging list does not establish stock or delivery timing.
| Format | Net mass | Planning use |
|---|---|---|
| Pail | 20 kg | Small-batch / trial |
| Drum | 50 kg | Standard |
| IBC tote | 1000 kg | Bulk |
What do these benchmarks establish before a production trial?
These source-stated benchmarks define questions to resolve with the manufacturing partner, including method, substrate and acceptance timing. They do not constitute certification or a guarantee for another construction. The following answers separate the 24-hour inspection, 48-hour cure reference and grade-specific coating results from a completed production validation.
Does a 24-hour inspection replace the 48-hour cure reference?
No. The ambient inspection follows 24 hours of conditioning; adhesive series separately state a 48-hour cure reference. Record both requirements and agree the final acceptance point.
Does the rigid-box temperature range certify ocean freight?
No. The −36°C and 80°C exposures are test conditions. They do not reproduce every shipping route, load or humidity cycle; validate the packed article for its intended distribution.
Is 420 m/min guaranteed for every folder-gluer job?
No. Up to 420 m/min is a series reference. Confirm board, coating, bead placement, applicator and compression conditions for the selected M-6140–M-6288 grade and actual line.
What must accompany the 3H and 1,000-rub figures?
LK1042 states pencil hardness 3H; LK1044 states no scratch after 1,000 rubs. Request the test method, substrate, cure conditions, load and evaluation criteria before comparing these figures with another product.
Does the 100°C boil result establish retort suitability?
No. LK1037 states no delamination after a 100°C boil for 2 hours. That result alone does not establish suitability for a different pressure, sterilization cycle, food contact or complete laminate construction.
What is needed before accepting a trial batch?
Identify grade, batch, substrates, setup, conditioning and acceptance method. Request current TDS/SDS and retain controls; catalogue benchmarks are not a batch-specific test certificate.
